If there is a problem, clean the micrometer and try to blow any debris out using compressed air, as there may be a chip stuck somewhere in the mechanism that moves the measuring rod. Dec 24, 2011 as a machinist, we must be able to measure what we produce. Calibration guidelines for micrometers using a fivepoint calibration method. The stage micrometer is 1 mm long with 100 divisions so each division of the stage micrometer is one onehundredth of a mm 0. Supermicrometer calibration micro precision provides calibration for all types of supermicrometer calibration and measuring instruments. Ts0071 outside micrometer calibration record sheet must be used. It is a must that a calibration lab will provide remarks regarding the observe parameters during the calibration process and reflect it on the certificate if those remarks support a certain measurement result. Stage micrometer or calibration grid the following procedure explains calibration of a microscope with 10x eyepiece lenses and 4x, 10x, 40x and possibly 100x objective lenses using a basic grid with smallest division 0.
The national bureau of standards was established by an act of congress on. Hb 145 was developed as a source of calibration procedures for weights and measures laboratories and covered mass, length and volume calibrations for field. So after some thinking i came across the right way to calibrate my central micrometer. They shall be calibrated or verified at specified intervals or prior to use, against measurement standards traceable to international or national standards. Standards and equipment used must have a valid calibration certificate 2. This is critical because these records will help you conduct similar calibration procedures in the future. General industrial practice is to confine thread calibration checks to. As a machinist, we must be able to measure what we produce. The history of the micrometer the word micrometer is a neoclassical coinage from greek micros, meaning small, and metron, meaning measure. Here are some guidelines for a fivepoint calibration on micrometers. Regular calibration intervals help ensure micrometer accuracy. Clean the outside micrometer s measuring surfaces and the gauge blocks to be used. We dont need to know the actual distance between marks on it.
The good laboratory practices glps, good measurement practices gmps, and standard operating procedures sops that have not been updated are available on the linked pages as scanned pdf copies. Scope this general procedure shall be used in the absence of any specific calibration procedure for rod type depth micrometers. Clean the outside micrometers measuring surfaces and the gauge blocks to be used. Micrometer calibration national physical laboratory. Please click on the link below sample to download a free. The calibration laboratory shall have a controlled ambient temperature between 68f and 73f inclusive. Standards and equipment used must have a valid calibration certificate. Mar 20, 20 so after some thinking i came across the right way to calibrate my central micrometer. For each test characteristic, the app offers a test method and acceptable limits. Now the next time when you calibrate the micrometer, the result should be the same as you got on the previous occasion.
You have calibrated a micrometer and recorded the details in a proper log book. Hb 145 was developed as a source of calibration procedures for weights and measures laboratories and covered mass, length and volume calibrations for field standards used in the commercial marketplace. Calibration procedure for inside micrometer, micrometer heads, calipers and depth micrometers, t. Scope this general procedure shall be used in the absence of any specific calibration procedure for outside micrometers. Example uncertainty budget for the calibration of a 0 25 mm micrometer. Always check the accuracy of a mic with a gauge block if it has been. E1 1 introduction this procedure describes the steps taken when calibrating vernier calliper gauges of any dimension using the din 862 standard. A set of operations which establishes, under speci. Sop 6 calibration of vernier calliper gauges issue no. Master gauge block set calibrated outside micrometer of similar range note. Calpro sample procedure cp02e outside micrometer and micrometer head sample procedure 2 standards and calibrating equipment. Outside micrometer calibration purpose the purpose of this procedure is to provide general instructions for the calibration of outside micrometers with vernier, digital, or combination scales. Length measuring elements such as micrometer screws, dial micrometers, and.
Therefore, the calibration equipment accuracy must be. Nbs handbook 145, 1986, handbook for the quality assurance of metrological measurements, by john k. Should you be unfortunate and drop a micrometer, do not use until the micrometer has been recalibratedrepaired by an appropriate repair agent. Clean the depth micrometer s measuring surfaces and the gauge blocks to be used. A thorough calibration of a parallel thread gage internal or external can be very time consuming, but with the proper instrument, it doesnt have to. This paper describes the method for calibration of large sized micrometers performed at the government of the hong kong special. Make sure the spindle and anvil faces are flat, free of pinholes, and are clean. Calibration shall be performed in an environment that conforms to manufacturer specifications. Zero the depth micrometer at the start when placed directly on the granite plate. Calibration, the calibration administrator shall ensure that the equipment is identified held for calibration and segregated from use until the calibration effort is completed. Equipment calibration record calibration procedure no. Stop using a caliper that fails to meet calibration.
Use this free procedure for outside micrometer calibration as a starting point for. Calibration procedure for calibration of external micrometer. Apr 01, 2004 regular calibration intervals help ensure micrometer accuracy. The inside micrometer calibration procedure app provides a stepbystep process to calibrate the measuring instrument. Hint, you move the decimal point over three places to the right to change mm to micrometers. Oppermann is out of print and the majority of content has been updated and published in the publications noted below. Calibration procedure for inside micrometer, micrometer. The merriamwebster collegiate dictionary says that english got it from french and that its first known appearance in english writing was in 1670. The calibration procedure consists of four steps including inspecting the anvils and thimble, the measuring scale, and rod inserts. Check to see if the spindle feels smooth while moving the micrometer from 0. The example calibration procedure lists gage blocks as the calibration equipment. Calibration and related measurement services of the. Scope of calibration service at each of our 16 accredited calibration laboratories is shown below. An iso 17025 accredited calibration lab follows the format of an accredited calibration certificate requirements.
Always ensure that both the micrometer and workpiece have stabilised to ambient temperature before measurements are taken. The calibration laboratory shall have a controlled ambient. Zero the outside micrometer at the start and adjust as required by the. The dept micrometer will hereafter be referred to as the instrument under test iut. This procedure describes the calibration of outside micrometer. The standard used in calibrating measuring gages must possess an accuracy greater than a 4. Major diameter external or minor diameter internal thread halfangle and. Look at the frame, for signs of damage, such as indications that it was dropped on the floor. In the picture above the eyepiece reticle is 10mm long divided into 100 divisions with major markings every 1 mm. Procedure preliminary instructions and notes read this entire procedure before beginning the calibration. Depth micrometer calibration purpose the purpose of this procedure is to provide general instructions for the calibration of rod type depth micrometers. Digital depth micrometers only need one scale to be verified. It is wise to assess the situation before the calibration process.
Using the iso guide to the expression of uncertainty in. The stage micrometer is 1mm long divided into 100 units, each unit is. Clean the micrometer after use with a lint free paper or cloth. Uncertainty budget for measurement using 025 mm micrometer in a workshop environment. Inside micrometer calibration procedure form mobile app. Grasp the micrometer frame in your palm and turn the thimble with your thumb and finger. Iso 9001 calibration requirements iso 9001 requires calibration for gage blocks, micrometers, pin gages, calipers and thread gauges. Outside micrometer calibration procedure memorial university. How to calibrate a starrett micrometer career trend. Micrometer calibration micrometer calibration services. If we look closer at the contributions, we can derive several very useful pieces of information, that can help us decide where.
Calpro sample procedure cp02e outside micrometer and micrometer head sample procedure 1 cp02e outside micrometer and micrometer head sample procedure revision date. Standard operating procedure for the calibration of weight carts 33 the essential portions of sop 29, standard operating procedure for assignment of uncertainty were first published in 1994 for the ncsl conference and symposium and to assist state weights and. Our technicians have years of experience with precision measurement of dimensional hand tools and work with stage micrometers, depth micrometers, inside and outside micrometers, digital micrometers, thread micrometers, anvil or blade micrometers, and more. Check to see if the spindle feels smooth while moving the micrometer from 0 25ml. This short video will reveal basic usage and calibration of a typical inch outside micrometer. Draper laboratory csdl, or another qualified calibration service, will perform all necessary inspections, repairs, and calibrations in accordance with the requirement established by milstd45662. Check the tolerance of each micrometer with a mitutoyo block set to determine the confidence. Hold the mic squarely with the work or false readings will result. The kit contains a 47 piece grade 1 metric gauge block set, with each gauge made of hardened alloy steel with a high quality surface finish. Small tool instruments and data management calibration. This procedure describes the calibration of outside micrometer and micrometer head. These readings are then used to calculate the calibration factor for each objective. The 7151 is a comprehensive kit for dimensional calibration applications including verniers, calipers, micrometers, and depth gauges.